Gasketed plate heat exchanger substations

District Heating networks Base Substations. 50 ÷ 6.000 kW.

AMARCDHS - Torino

standards

ACQUA_CALDA ACQUA_SURRISCALDATA ACS ACS_DIRETTA SOLO_RISC
From 50 to 6.000 kW
Models "Torino" e "Varese"

Gasketed plate heat exchangers.
50 to 6.000 kW standard package.
With heat meter, control and security devices.
PN 25 on primary circuit.
Twin heat exchanger version (max 5.000 kW).
For hot and superheated water networks.
Heating, cooling and DHW versions.
User customizable. CE / PED Certification.
Small size. Easy to disassemble and move.
Ready for remote metering and remote control.
Flow rate, power and return temperature limitation.
Temperature management for fixed-point or external temperature compensated.

Strength

RANGE AND PERFORMANCES

  • Complete range from 50 to 6000 kW for district heating and DHW with hot and superheated water networks.
  • Ready in stock delivery ready for standard models.
  • Mass production ensures high quality level.
  • Numerous options available.
  • Specifications, diagrams and drawings.
  • Preset typical insatallation schemes available.

SPECIAL FUNCTIONS AND SERVICES

  • Metering system sealing and safety lock especially on probes.
  • Technical assistance and training.
  • Internal Service specialized in district heating with availability on-call service 24/24 h.
  • Electrical and mechanical installation.
  • Transport and positioning.

CONSTRUCTION

  • Extremely compact, easy to transport and install.
  • Mechanical design primary circuit: PN 16/135 °C standard.
  • Primary circuit in accordante with high quality industrial standards (ASTM A106 GR B, tig welded with CE/PED certified x-ray).
  • Wells for probes and instruments in Inox AISI 316L steel and flat sealing gasket with Teflon.
  • Ready for drainage filter (serial and parallel).
  • Ready for installation of optional booster pump.
  • Pressure switch and temperature gauges on all circuits.
  • Vents and drains on all circuits.
  • Special shutter regulation valves for anti-noise district heating applications even with very high deltaP values.
  • Galvanization treatment on secondary circuit.
  • Metal control board IP 55 with double lock.
  • Heat meter inside control board.
  • CE/PED approved including also heat exchanger rupture.
  • Extension of CE / PED certification to the whole set "Power Station", as an alternative to the Ispesl procedures.
  • Wiring and probe cable protected by sheath.
  • Amarc DHS components supplier: ALFA LAVAL (heat exchangers) | SIEMENS (heat meters, regulation valves, actuators) | KAMSTRUP (heat meters) | KSB (valves and check valves) | NAVAL OY (ball valves) | IVR (shut-off valves) | CALEFFI/WATTS (security valve) | SAMSON (self-operated valves) | WILO (pumps) | HONEYWELL (actuators, 2-3 ways valves)

Common schematic

Working Conditions

HOT WATER SUPERHEATED WATER COOLING DIRECT H.D.W. (Hot Domestic Water) INDIRECT H.D.W. (Hot Domestic Water)
THERMAL DESIGNPRIMARY CIRCUIT 90/65°C 115/65°C 7/11°C 85/55°C 85/55°C
THERMAL DESIGNSECONDARY CIRCUIT 60/75°C 60/75°C 14/8°C 25/50°C 30/55°C
PRESSURE LOSS (Δp) @ NOMINAL CONDITIONS - CIRCUITS 1 & 2 < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 15 w.c.m. (1°)< 6 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°)
MECHANICAL DESIGNCIRCUITS 1 & 2 PN25PN16 PN16PN10 PN25PN10
THERMAL OVERSIZING 20%
CERTIFICATION DESIGN CE/PED - ISPESL
Δp EMERGENCY CLOSEDOWNREGULATION VALVE 25 barg
OPTIMIZATIONS FLOW RATE LIMITATION, REMOTE SIMULTANEOUS TEMPERATURE AND POWER SETTING

Our models

Type Model DN 1°
(in/out)
DN 2°
(in/out)
PN 1°
(bar)
PN 2°
(bar)
Tmax 1°
(°C)
Tmax 2°
(°C)
Dimensions
(mm)
Weight
(kg)
Hot Water Heating Gasketed TORINO 1000 C 65/65 100/100 16.0 10.0 110.0 95.0 2500x600x1650 747
Overheated Water Heating Gasketed TORINO 1000 S 40/50 100/100 16.0 10.0 130.0 95.0 2500x600x1650 724
Hot Water DHW-Direct Gasketed TORINO 100 C ACS D 25/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 265
Hot Water DHW-Indirect Gasketed TORINO 100 C ACS I 25/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 268
Hot Water Heating Gasketed TORINO 100 C 25/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 274
Overheated Water DHW-Direct Gasketed TORINO 100 S ACS D 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 252
Overheated Water DHW-Indirect Gasketed TORINO 100 S ACS I 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 255
Overheated Water Heating Gasketed TORINO 100 S 20/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 257
Overheated Water Heating Gasketed TORINO 1150 S 40/65 100/100 16.0 10.0 130.0 95.0 2500x600x1650 756
Hot Water Heating Gasketed TORINO 1250 C 80/80 125/125 16.0 10.0 110.0 95.0 2500x850x1800 864
Hot Water Heating Gasketed TORINO 125 C 25/25 50/50 16.0 10.0 110.0 95.0 1800x600x1650 287
Overheated Water Heating Gasketed TORINO 125 S 20/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 274
Overheated Water Heating Gasketed TORINO 1300 S 50/65 100/100 16.0 10.0 130.0 95.0 2500x600x1650 804
Hot Water Heating Gasketed TORINO 1500 C 100/100 150/150 16.0 10.0 110.0 95.0 2500x850x1800 990
Overheated Water Heating Gasketed TORINO 1500 S 50/65 100/100 16.0 10.0 130.0 95.0 2500x600x1650 804
Hot Water DHW-Direct Gasketed TORINO 150 C ACS D 40/25 50/50 16.0 10.0 110.0 95.0 1800x600x1650 281
Hot Water DHW-Indirect Gasketed TORINO 150 C ACS I 40/25 50/50 16.0 10.0 110.0 95.0 1800x600x1650 284
Hot Water Heating Gasketed TORINO 150 C 40/25 50/50 16.0 10.0 110.0 95.0 1800x600x1650 291
Overheated Water DHW-Direct Gasketed TORINO 150 S ACS D 25/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 265
Overheated Water DHW-Indirect Gasketed TORINO 150 S ACS I  25/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 272
Overheated Water Heating Gasketed TORINO 150 S 25/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 274
Hot Water Heating Gasketed TORINO 175 C 40/25 50/50 16.0 10.0 110.0 95.0 1800x600x1650 296
Overheated Water Heating Gasketed TORINO 175 S 25/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 279
Hot Water Heating Gasketed TORINO 2000 C 100/100 150/150 16.0 10.0 110.0 95.0 2500x850x1800 1210
Overheated Water Heating Gasketed TORINO 2000 S 80/80 150/150 16.0 10.0 130.0 95.0 2500x850x1800 980
Hot Water DHW-Direct Gasketed TORINO 200 C ACS D 40/40 50/50 16.0 10.0 110.0 95.0 1800x600x1650 282
Hot Water DHW-Indirect Gasketed TORINO 200 C ACS I 40/40 50/50 16.0 10.0 110.0 95.0 1800x600x1650 287
Hot Water Heating Gasketed TORINO 200 C 40/40 50/50 16.0 10.0 110.0 95.0 1800x600x1650 297
Overheated Water DHW-Direct Gasketed TORINO 200 S ACS D 25/25 50/50 16.0 10.0 140.0 95.0 1800x600x1650 281
Overheated Water DHW-Indirect Gasketed TORINO 200 S ACS I 25/25 50/50 16.0 10.0 140.0 95.0 1800x600x1650 290
Overheated Water Heating Gasketed TORINO 200 S 40/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 292
Overheated Water Heating Gasketed TORINO 2500 S 80/80 150/150 16.0 10.0 130.0 95.0 2500x850x1800 1120
Hot Water Heating Gasketed TORINO 250 C 40/40 50/50 16.0 10.0 110.0 95.0 1800x600x1650 313
Overheated Water Heating Gasketed TORINO 250 S 25/25 50/50 16.0 10.0 130.0 95.0 1800x600x1650 297
Hot Water DHW-Direct Gasketed TORINO 300 C ACS D 40/40 50/50 16.0 10.0 110.0 95.0 1800x600x1650 296
Hot Water DHW-Indirect Gasketed TORINO 300 C ACS I 40/40 65/65 16.0 10.0 110.0 95.0 1800x600x1650 303
Hot Water Heating Gasketed TORINO 300 C 40/40 65/65 16.0 10.0 110.0 95.0 1800x600x1650 318
Overheated Water DHW-Direct Gasketed TORINO 300 S ACS D 25/25 65/65 16.0 10.0 140.0 95.0 1800x600x1650 282
Overheated Water DHW-Indirect Gasketed TORINO 300 S ACS I 25/25 65/65 16.0 10.0 140.0 95.0 1800x600x1650 295
Overheated Water Heating Gasketed TORINO 300 S 25/25 65/65 16.0 10.0 130.0 95.0 1800x600x1650 304
Hot Water Heating Gasketed TORINO 350 C 40/40 65/65 16.0 10.0 110.0 95.0 1800x600x1650 357
Overheated Water Heating Gasketed TORINO 350 S 40/25 65/65 16.0 10.0 130.0 95.0 1800x600x1650 308
Hot Water Heating Gasketed TORINO 400 C 40/50 80/80 16.0 10.0 110.0 95.0 2500x600x1650 596
Overheated Water DHW-Direct Gasketed TORINO 400 S ACS D 25/40 65/65 16.0 10.0 140.0 95.0 1800x600x1650 293
Overheated Water DHW-Indirect Gasketed TORINO 400 S ACS I 25/40 65/65 16.0 10.0 140.0 95.0 1800x600x1650 310
Overheated Water Heating Gasketed TORINO 400 S 25/40 65/65 16.0 10.0 130.0 95.0 1800x600x1650 316
Hot Water Heating Gasketed TORINO 500 C 50/50 80/80 16.0 10.0 110.0 95.0 2500x600x1650 633
Overheated Water DHW-Direct Gasketed TORINO 500 S ACS D 40/40 65/65 16.0 10.0 140.0 95.0 1800x600x1650 298
Overheated Water DHW-Indirect Gasketed TORINO 500 S ACS I 40/40 80/80 16.0 10.0 140.0 95.0 1800x600x1650 320
Overheated Water Heating Gasketed TORINO 500 S 40/40 80/80 16.0 10.0 130.0 95.0 1800x600x1650 325
Hot Water DHW-Direct Gasketed TORINO 50 C ACS D 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 265
Hot Water DHW-Indirect Gasketed TORINO 50 C ACS I 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 265
Hot Water Heating Gasketed TORINO 50 C 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 268
Overheated Water DHW-Direct Gasketed TORINO 50 S ACS D 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 252
Overheated Water DHW-Indirect Gasketed TORINO 50 S ACS I 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 252
Overheated Water Heating Gasketed TORINO 50 S 20/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 255
Hot Water Heating Gasketed TORINO 600 C 50/65 80/80 16.0 10.0 110.0 95.0 2500x600x1650 649
Overheated Water Heating Gasketed TORINO 600 S 40/40 80/80 16.0 10.0 130.0 95.0 2500x600x1650 627
Hot Water Heating Gasketed TORINO 700 C 50/65 80/80 16.0 10.0 110.0 95.0 2500x600x1650 685
Overheated Water Heating Gasketed TORINO 700 S 40/50 80/80 16.0 10.0 130.0 95.0 2500x600x1650 631
Hot Water DHW-Direct Gasketed TORINO 75 C ACS D 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 265
Hot Water DHW-Indirect Gasketed TORINO 75 C ACS I 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 266
Hot Water Heating Gasketed TORINO 75 C 20/20 50/50 16.0 10.0 110.0 95.0 1800x600x1650 269
Overheated Water DHW-Direct Gasketed TORINO 75 S ACS D 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 252
Overheated Water DHW-Indirect Gasketed TORINO 75 S ACS I 20/20 50/50 16.0 10.0 140.0 95.0 1800x600x1650 254
Overheated Water Heating Gasketed TORINO 75 S 20/20 50/50 16.0 10.0 130.0 95.0 1800x600x1650 255
Hot Water Heating Gasketed TORINO 800 C 65/65 100/100 16.0 10.0 110.0 95.0 2500x600x1650 695
Overheated Water Heating Gasketed TORINO 800 S 40/50 100/100 16.0 10.0 130.0 95.0 2500x600x1650 678
Hot Water Heating Gasketed TORINO 900 C 65/65 100/100 16.0 10.0 110.0 95.0 2500x600x1650 737
Overheated Water Heating Gasketed TORINO 900 S 40/50 100/100 16.0 10.0 130.0 95.0 2500x600x1650 681
Hot Water Heating Gasketed VARESE 1000 C 80/80 100/100 16.0 10.0 110.0 95.0 2800x950x2130 3080
Overheated Water Heating Gasketed VARESE 1000 S 50/50 100/100 16.0 10.0 130.0 95.0 2800x950x2130 3050
Hot Water Heating Gasketed VARESE 1250 C 100/100 100/100 16.0 10.0 110.0 95.0 2800x950x2130 3080
Overheated Water Heating Gasketed VARESE 1250 S 65/65 100/100 16.0 10.0 130.0 95.0 2800x950x2130 3050
Hot Water Heating Gasketed VARESE 1500 C 100/100 125/125 16.0 10.0 110.0 95.0 2800x950x2130 3180
Overheated Water Heating Gasketed VARESE 1500 S 80/80 125/125 16.0 10.0 130.0 95.0 2800x950x2130 3150
Hot Water Heating Gasketed VARESE 2000 C 100/100 125/125 16.0 10.0 110.0 95.0 2800x950x2130 3230
Overheated Water Heating Gasketed VARESE 2000 S 80/80 150/150 16.0 10.0 130.0 95.0 2800x950x2130 3200
Hot Water Heating Gasketed VARESE 2500 C 125/125 150/150 16.0 10.0 110.0 95.0 2800x950x2130 3230
Overheated Water Heating Gasketed VARESE 2500 S 80/80 150/150 16.0 10.0 130.0 95.0 2800x950x2130 3200
Hot Water Heating Gasketed VARESE 3000 C 125/125 150/150 16.0 10.0 110.0 95.0 2800x950x2130 3280
Overheated Water Heating Gasketed VARESE 3000 S 100/100 200/200 16.0 10.0 130.0 95.0 2800x950x2130 3250
Hot Water Heating Gasketed VARESE 4000 C 150/150 200/200 16.0 10.0 110.0 95.0 2800x950x2130 3290
Overheated Water Heating Gasketed VARESE 4000 S 100/100 200/200 16.0 10.0 130.0 95.0 2800x950x2130 3250
Hot Water Heating Gasketed VARESE 5000 C 150/150 250/250 16.0 10.0 110.0 95.0 2800x950x2130 3300
Overheated Water Heating Gasketed VARESE 5000 S 100/100 250/250 16.0 10.0 130.0 95.0 2800x950x2130 3250
Overheated Water Heating Gasketed VARESE 6000 S 125/125 250/250 16.0 10.0 130.0 95.0 2800x950x2130 3350