30÷150 kW heating and up to 180 kW Hot Domestic Water production.
From 10 to 150 kW heating and max 180 kW DHW.
Combi version: heating + DHW.
With heat meter, control and security devices.
PN 25 on primary circuit.
For hot and superheated water networks.
For heating and DHW.
User customizable.
CE / PED Certification.
Small size.
Easy maintenance.
Ready for remote metering and remote control.
Flow rate, power and return temperature limitation.
Temperature management for fixed-point or external temperature compensated.
HOT WATER | SUPERHEATED WATER | DIRECT H.D.W. | INDIRECT H.D.W. | ||
---|---|---|---|---|---|
THERMAL DESIGNPRIMARY CIRCUIT | 90/65°C | 115/65°C | 85/55°C | 85/55°C | |
THERMAL DESIGNSECONDARY CIRCUITT | 60/75°C | 60/75°C | 25/50°C | 30/55°C | |
PRESSURE DROP (Δp) @ NOMINAL CONDITIONS - CIRCUITS 1 & 2 | < 10 w.c.m. (1°)< 3 w.c.m. (2°) | < 10 w.c.m. (1°)< 3 w.c.m. (2°) | < 10 w.c.m. (1°)< 3 w.c.m. (2°) | < 10 w.c.m. (1°)< 3 w.c.m.. (2°) | |
MECHANICAL DESIGNCIRCUITS 1 & 2 | PN25 (1°)PN16/PN10 (2°) | PN25 (1°)PN10 (2°) | |||
THERMAL OVERSIZING | 20% | ||||
CERTIFICATION DESIGN | CE/PED - ISPESL | ||||
ΔP EMERGENCY CLOSEDOWNREGULATION VALVE | 25 barg | ||||
OPTIMIZATIONS | FLOW RATE LIMITATION, REMOTE SIMULTANEOUS TEMPERATURE AND POWER SETTING |
Type | Model | DN 1° (in/out) |
DN 2° (in/out) |
PN 1° (bar) |
PN 2° (bar) |
Tmax 1° (°C) |
Tmax 2° (°C) |
Dimensions (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|
Hot Water DHW-Direct Brazed plate | FONDO 120 C ACS D | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 60 |
Hot Water DHW-Indirect Brazed plate | FONDO 120 C ACS I | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 65 |
Hot Water Heating Brazed plate | FONDO 120 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 65 |
Overheated Water DHW-Direct Brazed plate | FONDO 120 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 60 |
Overheated Water DHW-Indirect Brazed plate | FONDO 120 S ACS I | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 65 |
Overheated Water Heating Brazed plate | FONDO 120 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 65 |
Overheated Water DHW-Direct Brazed plate | FONDO 150 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 65 |
Overheated Water DHW-Indirect Brazed plate | FONDO 150 S ACS I | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 70 |
Overheated Water Heating Brazed plate | FONDO 150 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 70 |
Overheated Water DHW-Direct Brazed plate | FONDO 180 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 70 |
Hot Water DHW-Direct Brazed plate | FONDO 30 C ACS D | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 45 |
Hot Water DHW-Indirect Brazed plate | FONDO 30 C ACS I | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 50 |
Hot Water Heating Brazed plate | FONDO 30 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 50 |
Overheated Water DHW-Direct Brazed plate | FONDO 30 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 45 |
Overheated Water DHW-Indirect Brazed plate | FONDO 30 S ACS I | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 50 |
Overheated Water Heating Brazed plate | FONDO 30 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 50 |
Hot Water DHW-Direct Brazed plate | FONDO 60 C ACS D | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 50 |
Hot Water DHW-Indirect Brazed plate | FONDO 60 C ACS I | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 55 |
Hot Water Heating Brazed plate | FONDO 60 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 55 |
Overheated Water DHW-Direct Brazed plate | FONDO 60 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 50 |
Overheated Water DHW-Indirect Brazed plate | FONDO 60 S ACS I | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 55 |
Overheated Water Heating Brazed plate | FONDO 60 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 55 |
Hot Water DHW-Direct Brazed plate | FONDO 90 C ACS D | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 55 |
Hot Water DHW-Indirect Brazed plate | FONDO 90 C ACS I | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 60 |
Hot Water Heating Brazed plate | FONDO 90 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 60 |
Overheated Water DHW-Direct Brazed plate | FONDO 90 S ACS D | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 55 |
Overheated Water DHW-Indirect Brazed plate | FONDO 90 S ACS I | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 60 |
Overheated Water Heating Brazed plate | FONDO 90 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 60 |
Hot Water Heating and DHW-direct Brazed plate | FONDO COMBI 120 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 80 |
Overheated Water Heating and DHW-direct Brazed plate | FONDO COMBI 120 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 80 |
Overheated Water Heating and DHW-direct Brazed plate | FONDO COMBI 150 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 85 |
Hot Water Heating and DHW-direct Brazed plate | FONDO COMBI 30 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 65 |
Overheated Water Heating and DHW-direct Brazed plate | FONDO COMBI 30 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 65 |
Hot Water Heating and DHW-direct Brazed plate | FONDO COMBI 60 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 70 |
Overheated Water Heating and DHW-direct Brazed plate | FONDO COMBI 60 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 70 |
Hot Water Heating and DHW-direct Brazed plate | FONDO COMBI 90 C | 1” | 1½” | 25.0 | 10.0 | 110.0 | 95.0 | 750x930x260 | 75 |
Overheated Water Heating and DHW-direct Brazed plate | FONDO COMBI 90 S | 1” | 1½” | 25.0 | 10.0 | 130.0 | 95.0 | 750x930x260 | 75 |