Twin copper brazed heat exchanger substations

District Heating networks Twin Base Substations. Up to 5.000 kW

SST_DOPPIA

standards

ACQUA_CALDA ACQUA_SURRISCALDATA SOLO_RISC
Up to 5.000 kW
Model "Milano"

Gasketed or brazed plate heat exchangers.
Up to 5.000 kW standard package.
With heat meter, control and security devices.
PN 25 on primary circuit.
For hot, refrigerated and superheated water networks. Cooling, heating and/or DHW version
User customizable. CE / PED Certification.
Small size. Easy to disassemble and move.
Ready for remote metering and remote control.
Flow rate, power and return temperature limitation.
Temperature management for fixed-point or external temperature compensated.

Strength

RANGE AND PERFORMANCES

  • Complete range from 10 to 6000 kW for district heating and DHW with hot and superheated water networks.
  • Ready in stock delivery ready for standard models.
  • Mass production ensures high quality level.
  • Numerous options available.
  • Specifications, diagrams and drawings.
  • Preset typical insatallation schemes available.

SPECIAL FUNCTIONS AND SERVICES

  • Metering system sealing and safety lock especially on probes.
  • Electrical panel with sequence management function.
  • Technical assistance and training.
  • Internal Service specialized in district heating with availability on-call service 24/24 h.
  • Electrical and mechanical installation.
  • Insulation of the heat exchanger and pipes.
  • Transport and positioning.

CONSTRUCTION

  • Extremely compact, easy to transport and install.
  • Mechanical design primary circuit: PN 25/135 °C standard.
  • Primary circuit in accordante with high quality industrial standards (ASTM A106 GR B, tig welded with CE/PED certified x-ray).
  • Wells for probes and instruments in Inox AISI 316L steel and flat sealing gasket with Teflon.
  • Ready for drainage filter (serial and parallel).
  • Ready for installation of optional booster pump.
  • Pressure switch and temperature gauges on all circuits.
  • Vents and drains on all circuits.
  • Special shutter regulation valves for anti-noise district heating applications even with very high deltaP values.
  • Galvanization treatment on secondary circuit.
  • Metal control board IP 55 with double lock.
  • Heat meter inside control board.
  • CE/PED approved including also heat exchanger rupture.
  • Extension of CE / PED certification to the whole set "Power Station", as an alternative to the Ispesl procedures.
  • Wiring and probe cable protected by sheath.
  • Amarc DHS components supplier: ALFA LAVAL (heat exchangers) | DANFOSS ( Control valves, actuators, and regulators) | SIEMENS (heat meters, regulation valves, actuators) | KAMSTRUP (heat meters) | BRANDONI (valves and check valves) | NAVAL OY (ball valves) | IVR (shut-off valves) | CALEFFI/WATTS (security valve) | WILO (pumps) | HONEYWELL (actuators, 2-3 ways valves)

Common schematic

Working Conditions

HOT WATER SUPERHEATED WATER COOLING DIRECT H.D.W. (Hot Domestic Water) INDIRECT H.D.W. (Hot Domestic Water)
THERMAL DESIGNPRIMARY CIRCUIT 90/65°C 115/65°C 7/11°C 85/55°C 85/55°C
THERMAL DESIGNSECONDARY CIRCUIT 60/75°C 60/75°C 14/8°C 25/50°C 30/55°C
PRESSURE LOSS (Δp) @ NOMINAL CONDITIONS - CIRCUITS 1 & 2 < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 15 w.c.m. (1°)< 6 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°) < 10 w.c.m. (1°)< 3 w.c.m. (2°)
MECHANICAL DESIGNCIRCUITS 1 & 2 PN25PN16 PN16PN10 PN25PN10
THERMAL OVERSIZING 20%
CERTIFICATION DESIGN CE/PED - ISPESL
Δp EMERGENCY CLOSEDOWNREGULATION VALVE 25 barg
OPTIMIZATIONS FLOW RATE LIMITATION, REMOTE SIMULTANEOUS TEMPERATURE AND POWER SETTING

Our models

Type Model DN 1°
(in/out)
DN 2°
(in/out)
PN 1°
(bar)
PN 2°
(bar)
Tmax 1°
(°C)
Tmax 2°
(°C)
Dimensions
(mm)
Weight
(kg)
Hot Water Heating Brazed plate MILANO 1000 C D 80/80 100/100 25.0 10.0 110.0 95.0 2300x1450x1750 700
Overheated Water Heating Brazed plate MILANO 1000 S D 50/65 100/125 25.0 10.0 130.0 95.0 2300x1450x1750 650
Hot Water Heating Brazed plate MILANO 1250 C D 80/80 125/125 25.0 10.0 110.0 95.0 2300x1450x1750 750
Overheated Water Heating Brazed plate MILANO 1250 S D 65/65 125/125 25.0 10.0 130.0 95.0 2300x1450x1750 650
Hot Water Heating Brazed plate MILANO 1500 C D 80/100 125/125 25.0 10.0 110.0 95.0 2300x1450x1750 850
Overheated Water Heating Brazed plate MILANO 1500 S D 65/65 125/150 25.0 10.0 130.0 95.0 2300x1450x1750 700
Hot Water Heating Brazed plate MILANO 2000 C D 100/100 150/150 25.0 10.0 110.0 95.0 2300x1450x1750 900
Overheated Water Heating Brazed plate MILANO 2000 S D 80/80 150/150 25.0 10.0 130.0 95.0 2300x1450x1750 800
Hot Water Heating Brazed plate MILANO 2500 C D 125/125 200/200 25.0 10.0 110.0 95.0 2300x1450x1750 950
Overheated Water Heating Brazed plate MILANO 2500 S D 80/80 150/200 25.0 10.0 130.0 95.0 2300x1450x1750 850
Hot Water Heating Brazed plate MILANO 3000 C D 125/150 200/200 25.0 10.0 110.0 95.0 2300x1450x1750 1150
Overheated Water Heating Brazed plate MILANO 3000 S D 80/100 200/200 25.0 10.0 130.0 95.0 2300x1450x1750 900
Hot Water Heating Brazed plate MILANO 3500 C D 150/150 200/200 25.0 10.0 110.0 95.0 2300x1450x1750 1350
Overheated Water Heating Brazed plate MILANO 3500 S D 100/100 200/200 25.0 10.0 130.0 95.0 2300x1450x1750 900
Overheated Water Heating Brazed plate MILANO 4000 S D 100/125 250/250 25.0 10.0 130.0 95.0 2300x1450x1750 1000
Overheated Water Heating Brazed plate MILANO 4500 S D 100/125 250/250 25.0 10.0 130.0 95.0 2300x1450x1750 1200
Overheated Water Heating Brazed plate MILANO 5000 S D 125/125 250/250 25.0 10.0 130.0 95.0 2300x1450x1750 1350